  • Feasibility of Using a Novel 2.45 GHz Double Short Distance Slot Coaxial Antenna for Minimally Invasive Cancer Breast Microwave Ablation Therapy: Computational Model, Phantom, and In Vivo Swine Experimentation.

    abstract::Microwave ablation (MWA) by using coaxial antennas is a promising alternative for breast cancer treatment. A double short distance slot coaxial antenna as a newly optimized applicator for minimally invasive treatment of breast cancer is proposed. To validate and to analyze the feasibility of using this method in clini...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2018/5806753

    authors: Ortega-Palacios R,Trujillo-Romero CJ,Cepeda Rubio MFJ,Vera A,Leija L,Reyes JL,Ramírez-Estudillo MC,Morales-Alvarez F,Vega-López MA

    更新日期:2018-05-08 00:00:00

  • Performance Analysis of Ten Common QRS Detectors on Different ECG Application Cases.

    abstract::A systematical evaluation work was performed on ten widely used and high-efficient QRS detection algorithms in this study, aiming at verifying their performances and usefulness in different application situations. Four experiments were carried on six internationally recognized databases. Firstly, in the test of high-q...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2018/9050812

    authors: Liu F,Liu C,Jiang X,Zhang Z,Zhang Y,Li J,Wei S

    更新日期:2018-05-08 00:00:00

  • Potential of Electrospun Poly(3-hydroxybutyrate)/Collagen Blends for Tissue Engineering Applications.

    abstract::In this work, tunable nonwoven mats based on poly(3-hydroxybutyrate) (PHB) and type I collagen (Coll) were successfully produced by electrospinning. The PHB/Coll weight ratio (fixed at 100/0, 70/30, and 50/50, resp.) was found to control the morphological, thermal, mechanical, and degradation properties of the mats. I...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2018/6573947

    authors: Salvatore L,Carofiglio VE,Stufano P,Bonfrate V,Calò E,Scarlino S,Nitti P,Centrone D,Cascione M,Leporatti S,Sannino A,Demitri C,Madaghiele M

    更新日期:2018-04-19 00:00:00

  • Detection of Heart Rate through a Wall Using UWB Impulse Radar.

    abstract::Measuring the physiological functions of the human body in a noncontact manner through walls is useful for healthcare, security, and surveillance. And radar technology can be used for this purpose. In this paper, a new method for detecting the human heartbeat using ultra wideband (UWB) impulse radar, which has advanta...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2018/4832605

    authors: Cho HS,Park YJ

    更新日期:2018-04-01 00:00:00

  • Towards Optimal Platform-Based Robot Design for Ankle Rehabilitation: The State of the Art and Future Prospects.

    abstract::This review aims to compare existing robot-assisted ankle rehabilitation techniques in terms of robot design. Included studies mainly consist of selected papers in two published reviews involving a variety of robot-assisted ankle rehabilitation techniques. A free search was also made in Google Scholar and Scopus by us...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章,评审

    doi:10.1155/2018/1534247

    authors: Miao Q,Zhang M,Wang C,Li H

    更新日期:2018-03-15 00:00:00

  • Social Robotics in Therapy of Apraxia of Speech.

    abstract::Apraxia of speech is a motor speech disorder in which messages from the brain to the mouth are disrupted, resulting in an inability for moving lips or tongue to the right place to pronounce sounds correctly. Current therapies for this condition involve a therapist that in one-on-one sessions conducts the exercises. Ou...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2018/7075290

    authors: Castillo JC,Álvarez-Fernández D,Alonso-Martín F,Marques-Villarroya S,Salichs MA

    更新日期:2018-03-11 00:00:00

  • An Automatic Bleeding Frame and Region Detection Scheme for Wireless Capsule Endoscopy Videos Based on Interplane Intensity Variation Profile in Normalized RGB Color Space.

    abstract::Wireless capsule endoscopy (WCE) is an effective video technology to diagnose gastrointestinal (GI) disease, such as bleeding. In order to avoid conventional tedious and risky manual review process of long duration WCE videos, automatic bleeding detection schemes are getting importance. In this paper, to investigate b...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2018/9423062

    authors: Kundu AK,Fattah SA,Rizve MN

    更新日期:2018-02-25 00:00:00

  • Analysis of a Pulse Rate Variability Measurement Using a Smartphone Camera.

    abstract:Background:Heart rate variability (HRV) provides information about the activity of the autonomic nervous system. Because of the small amount of data collected, the importance of HRV has not yet been proven in clinical practice. To collect population-level data, smartphone applications leveraging photoplethysmography (P...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2018/4038034

    authors: Bánhalmi A,Borbás J,Fidrich M,Bilicki V,Gingl Z,Rudas L

    更新日期:2018-02-05 00:00:00

  • A New Intelligent Medical Decision Support System Based on Enhanced Hierarchical Clustering and Random Decision Forest for the Classification of Alcoholic Liver Damage, Primary Hepatoma, Liver Cirrhosis, and Cholelithiasis.

    abstract::Diagnosis of liver disease principally depends on physician's subjective knowledge. Automatic prediction of the disease is a critical real-world medical problem. This work presents an EHC-ERF-based intelligence-integrated model purposive to predict different types of liver disease including alcoholic liver damage, pri...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2018/1469043

    authors: Singh A,Pandey B

    更新日期:2018-02-01 00:00:00

  • Real-Time EEG Signal Enhancement Using Canonical Correlation Analysis and Gaussian Mixture Clustering.

    abstract::Electroencephalogram (EEG) signals are usually contaminated with various artifacts, such as signal associated with muscle activity, eye movement, and body motion, which have a noncerebral origin. The amplitude of such artifacts is larger than that of the electrical activity of the brain, so they mask the cortical sign...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2018/5081258

    authors: Lin CT,Huang CS,Yang WY,Singh AK,Chuang CH,Wang YK

    更新日期:2018-01-15 00:00:00

  • Frame-Based CT Image Reconstruction via the Balanced Approach.

    abstract::Frame-based regularization method as one kind of sparsity representation method has been developed in recent years and has been proved to be an efficient method for CT image reconstruction. However, most of the developed CT image reconstruction methods are analysis-based frame methods. This paper proposes a novel fram...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/1417270

    authors: Zhou W,Xiang H

    更新日期:2017-01-01 00:00:00

  • A Systematic Review on Recent Advances in mHealth Systems: Deployment Architecture for Emergency Response.

    abstract::The continuous technological advances in favor of mHealth represent a key factor in the improvement of medical emergency services. This systematic review presents the identification, study, and classification of the most up-to-date approaches surrounding the deployment of architectures for mHealth. Our review includes...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/9186270

    authors: Gonzalez E,Peña R,Avila A,Vargas-Rosales C,Munoz-Rodriguez D

    更新日期:2017-01-01 00:00:00

  • Removal of Arterial Vessel Contributions in Susceptibility-Weighted Images for Quantification of Normalized Visible Venous Volume in Children with Sickle Cell Disease

    abstract:Purpose:To evaluate a new postprocessing framework that eliminates arterial vessel signal contributions in the quantification of normalized visible venous volume (NVVV, a ratio between venous and brain volume) in susceptibility-weighted imaging (SWI) exams in patients with sickle cell disease (SCD). Materials and Meth...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/5369385

    authors: Winchell AM,Song R,Loeffler RB,Wang WC,Hankins JS,Helton KJ,Hillenbrand CM

    更新日期:2017-01-01 00:00:00

  • A Numerical Investigation into the Effects of Overweight and Obesity on Total Knee Arthroplasty.

    abstract::Overweight and obesity increase risks of knee osteoarthritis, which is a major cause of disability. Severe knee osteoarthritis can be treated by knee arthroplasty. Total knee arthroplasty has been used in overweight and obese patients; however, clinical reports showed that the outcome of this group of patients was not...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/1496379

    authors: Wang C,Guo Y,Shi J,Chen W

    更新日期:2017-01-01 00:00:00

  • An Interpretable Classification Framework for Information Extraction from Online Healthcare Forums.

    abstract::Online healthcare forums (OHFs) have become increasingly popular for patients to share their health-related experiences. The healthcare-related texts posted in OHFs could help doctors and patients better understand specific diseases and the situations of other patients. To extract the meaning of a post, a commonly use...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/2460174

    authors: Gao J,Liu N,Lawley M,Hu X

    更新日期:2017-01-01 00:00:00

  • Development of Single-Channel Hybrid BCI System Using Motor Imagery and SSVEP.

    abstract::Numerous EEG-based brain-computer interface (BCI) systems that are being developed focus on novel feature extraction algorithms, classification methods and combining existing approaches to create hybrid BCIs. Several recent studies demonstrated various advantages of hybrid BCI systems in terms of an improved accuracy ...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/3789386

    authors: Ko LW,Ranga SSK,Komarov O,Chen CC

    更新日期:2017-01-01 00:00:00

  • Model of Murine Ventricular Cardiac Tissue for In Vitro Kinematic-Dynamic Studies of Electromagnetic and β-Adrenergic Stimulation.

    abstract::In a model of murine ventricular cardiac tissue in vitro, we have studied the inotropic effects of electromagnetic stimulation (frequency, 75 Hz), isoproterenol administration (10 μM), and their combination. In particular, we have performed an image processing analysis to evaluate the kinematics and the dynamics of be...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/4204085

    authors: Fassina L,Cornacchione M,Pellegrini M,Mognaschi ME,Gimmelli R,Isidori AM,Lenzi A,Magenes G,Naro F

    更新日期:2017-01-01 00:00:00

  • Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System.

    abstract::The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/4842072

    authors: Sim BK,Kim B,Kim MJ,Jeong GH,Ju KW,Shin YJ,Kim MY,Lee JH

    更新日期:2017-01-01 00:00:00

  • An Approach to Evaluate Blurriness in Retinal Images with Vitreous Opacity for Cataract Diagnosis.

    abstract::Cataract is one of the leading causes of blindness in the world's population. A method to evaluate blurriness for cataract diagnosis in retinal images with vitreous opacity is proposed in this paper. Three types of features are extracted, which include pixel number of visible structures, mean contrast between vessels ...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/5645498

    authors: Xiong L,Li H,Xu L

    更新日期:2017-01-01 00:00:00

  • Influence of Gait Speeds on Contact Forces of Lower Limbs.

    abstract::While walking with fast speed aims to promote health and fitness of individuals, the potential risk on lower limb joint loading across walking speed is still unknown. In order to determine the joint contact force loading associated with different walking speeds, fifteen young male and fifteen female participants perfo...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/6375976

    authors: Wang X,Ma Y,Hou BY,Lam WK

    更新日期:2017-01-01 00:00:00

  • A Fast SVM-Based Tongue's Colour Classification Aided by k-Means Clustering Identifiers and Colour Attributes as Computer-Assisted Tool for Tongue Diagnosis.

    abstract::In tongue diagnosis, colour information of tongue body has kept valuable information regarding the state of disease and its correlation with the internal organs. Qualitatively, practitioners may have difficulty in their judgement due to the instable lighting condition and naked eye's ability to capture the exact colou...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/7460168

    authors: Kamarudin ND,Ooi CY,Kawanabe T,Odaguchi H,Kobayashi F

    更新日期:2017-01-01 00:00:00

  • Fall Prevention Shoes Using Camera-Based Line-Laser Obstacle Detection System.

    abstract::Fall prevention is an important issue particularly for the elderly. This paper proposes a camera-based line-laser obstacle detection system to prevent falls in the indoor environment. When obstacles are detected, the system will emit alarm messages to catch the attention of the user. Because the elderly spend a lot of...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/8264071

    authors: Lin TH,Yang CY,Shih WP

    更新日期:2017-01-01 00:00:00

  • Twin SVM-Based Classification of Alzheimer's Disease Using Complex Dual-Tree Wavelet Principal Coefficients and LDA.

    abstract::Alzheimer's disease (AD) is a leading cause of dementia, which causes serious health and socioeconomic problems. A progressive neurodegenerative disorder, Alzheimer's causes the structural change in the brain, thereby affecting behavior, cognition, emotions, and memory. Numerous multivariate analysis algorithms have b...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/8750506

    authors: Alam S,Kwon GR,Kim JI,Park CS

    更新日期:2017-01-01 00:00:00

  • Gentamicin Released from Porous Scaffolds Fabricated by Stereolithography.

    abstract::Porous oligolactide-hydroxyapatite composite scaffolds were obtained by stereolithographic fabrication. Gentamicin was then coated on the scaffolds afterwards, to achieve antimicrobial delivery ability to treat bone infection. The scaffolds examined by stereomicroscope, SEM, and μCT-scan showed a well-ordered pore str...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/9547896

    authors: Channasanon S,Udomkusonsri P,Chantaweroad S,Tesavibul P,Tanodekaew S

    更新日期:2017-01-01 00:00:00

  • The Biomechanical Study of Extraforaminal Lumbar Interbody Fusion: A Three-Dimensional Finite-Element Analysis.

    abstract:OBJECTIVE:Finite-element method was used to evaluate biomechanics stability of extraforaminal lumbar interbody fusion (ELIF) under different internal fixation. METHODS:The L3-L5 level finite-element model was established to simulate decompression and internal fixation at L4-L5 segment. The intact finite model was trea...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/9365068

    authors: Yang M,Sun G,Guo S,Zeng C,Yan M,Han Y,Xia D,Zhang J,Li X,Xiang Y,Pan J,Li L,Tan J

    更新日期:2017-01-01 00:00:00

  • Semiautomatic Epicardial Fat Segmentation Based on Fuzzy c-Means Clustering and Geometric Ellipse Fitting.

    abstract::Automatic segmentation of particular heart parts plays an important role in recognition tasks, which is utilized for diagnosis and treatment. One particularly important application is segmentation of epicardial fat (surrounds the heart), which is shown by various studies to indicate risk level for developing various c...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/5817970

    authors: Zlokolica V,Krstanović L,Velicki L,Popović B,Janev M,Obradović R,Ralević NM,Jovanov L,Babin D

    更新日期:2017-01-01 00:00:00

  • Handling Data Skew in MapReduce Cluster by Using Partition Tuning

    abstract::The healthcare industry has generated large amounts of data, and analyzing these has emerged as an important problem in recent years. The MapReduce programming model has been successfully used for big data analytics. However, data skew invariably occurs in big data analytics and seriously affects efficiency. To overco...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/1425102

    authors: Gao Y,Zhou Y,Zhou B,Shi L,Zhang J

    更新日期:2017-01-01 00:00:00

  • Inertial Sensor-Based Motion Analysis of Lower Limbs for Rehabilitation Treatments

    abstract::The hemiplegic rehabilitation state diagnosing performed by therapists can be biased due to their subjective experience, which may deteriorate the rehabilitation effect. In order to improve this situation, a quantitative evaluation is proposed. Though many motion analysis systems are available, they are too complicate...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2017/1949170

    authors: Sun T,Li H,Liu Q,Duan L,Li M,Wang C,Liu Q,Li W,Shang W,Wu Z,Wang Y

    更新日期:2017-01-01 00:00:00

  • Modelling pH-Optimized Degradation of Microgel-Functionalized Polyesters.

    abstract::We establish a novel mathematical model to describe and analyze pH levels in the vicinity of poly(N-vinylcaprolactam-co-acetoacetoxyethyl methacrylate-co-N-vinylimidazole) (VCL/AAEM/VIm) microgel-functionalized polymers during biodegradation. Biodegradable polymers, especially aliphatic polyesters (polylactide/polygly...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2016/8125416

    authors: Bürgermeister L,Hermann M,Fehér K,Molano Lopez C,Pich A,Hannen J,Vogt F,Schulz W

    更新日期:2016-01-01 00:00:00

  • Length of Hospital Stay Prediction at the Admission Stage for Cardiology Patients Using Artificial Neural Network.

    abstract::For hospitals' admission management, the ability to predict length of stay (LOS) as early as in the preadmission stage might be helpful to monitor the quality of inpatient care. This study is to develop artificial neural network (ANN) models to predict LOS for inpatients with one of the three primary diagnoses: corona...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2016/7035463

    authors: Tsai PF,Chen PC,Chen YY,Song HY,Lin HM,Lin FM,Huang QP

    更新日期:2016-01-01 00:00:00

  • Dynamic Changes in Heart Rate Variability and Nasal Airflow Resistance during Nasal Allergen Provocation Test.

    abstract::Allergic rhinitis is a major chronic respiratory disease and an immunoneuronal disorder. We aimed at providing further knowledge on the function of the neural system in nasal allergic reaction. Here, a method to assess simultaneously the nasal airflow resistance and the underlying function of autonomic nervous system ...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1155/2016/1245418

    authors: Seppänen TM,Alho OP,Seppänen T

    更新日期:2016-01-01 00:00:00

  • Experimental feasibility study of estimation of the normalized central blood pressure waveform from radial photoplethysmogram.

    abstract::The feasibility of a novel system to reliably estimate the normalized central blood pressure (CBPN) from the radial photoplethysmogram (PPG) is investigated. Right-wrist radial blood pressure and left-wrist PPG were simultaneously recorded in five different days. An industry-standard applanation tonometer was employed...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1260/2040-2295.6.1.121

    authors: Zahedi E,Sohani V,Ali MA,Chellappan K,Beng GK

    更新日期:2015-01-01 00:00:00

  • Scheduling Patients' Appointments: Allocation of Healthcare Service Using Simulation Optimization.

    abstract::In the service industry, scheduling medical procedures causes difficulties for both patients and management. Factors such as fluctuations in customer demand and service time affect the appointment scheduling systems' performance in terms of, for example, patients' waiting time, idle time of resources, and total cost/p...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1260/2040-2295.6.2.259

    authors: Chenl PS,Robielos RA,Palaña PK,Valencia PL,Chen GY

    更新日期:2015-01-01 00:00:00

  • Integration of Value Stream Map and Healthcare Failure Mode and Effect Analysis into Six Sigma Methodology to Improve Process of Surgical Specimen Handling.

    abstract::Specimen handling is a critical patient safety issue. Problematic handling process, such as misidentification (of patients, surgical site, and specimen counts), specimen loss, or improper specimen preparation can lead to serious patient harms and lawsuits. Value stream map (VSM) is a tool used to find out non-value-ad...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1260/2040-2295.6.3.377

    authors: Hung SH,Wang PC,Lin HC,Chen HY,Su CT

    更新日期:2015-01-01 00:00:00

  • Automatic sleep staging using multi-dimensional feature extraction and multi-kernel fuzzy support vector machine.

    abstract::This paper employed the clinical Polysomnographic (PSG) data, mainly including all-night Electroencephalogram (EEG), Electrooculogram (EOG) and Electromyogram (EMG) signals of subjects, and adopted the American Academy of Sleep Medicine (AASM) clinical staging manual as standards to realize automatic sleep staging. Au...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1260/2040-2295.5.4.505

    authors: Zhang Y,Zhang X,Liu W,Luo Y,Yu E,Zou K,Liu X

    更新日期:2014-01-01 00:00:00

  • A robust electrode configuration for bioimpedance measurement of respiration.

    abstract::Electrode configuration is an important issue in the continuous measurement of respiration using impedance pneumography (IP). The robust configuration is usually confirmed by comparing the amplitude of the IP signals acquired with different electrode configurations, while the relative change in waveform and the effect...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1260/2040-2295.5.3.313

    authors: Wang HB,Yen CW,Liang JT,Wang Q,Liu GZ,Song R

    更新日期:2014-01-01 00:00:00

  • Accuracy of plantar electrodes compared with hand and foot electrodes in fat-free-mass measurement.

    abstract::This paper investigates the measurement of fat-free mass (FFM) by bioimpedance using foot-to-foot impedancemeters (FFI) with plantar electrodes measuring the foot-to-foot resistance R34 and hand-to-foot medical impedancemeters. FFM measurements were compared with corresponding data using Dual X-ray absorptiometry (DXA...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1260/2040-2295.5.2.123

    authors: Jaffrin MY,Bousbiat S

    更新日期:2014-01-01 00:00:00

  • The power of exercise-induced T-wave alternans to predict ventricular arrhythmias in patients with implanted cardiac defibrillator.

    abstract::The power of exercise-induced T-wave alternans (TWA) to predict the occurrence of ventricular arrhythmias was evaluated in 67 patients with an implanted cardiac defibrillator (ICD). During the 4-year follow-up, electrocardiographic (ECG) tracings were recorded in a bicycle ergometer test with increasing workload rangi...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1260/2040-2295.4.2.167

    authors: Burattini L,Man S,Sweene CA

    更新日期:2013-01-01 00:00:00

  • Evaluation of postprandial glucose excursion using a novel minimally invasive glucose area-under-the-curve monitoring system.

    abstract:OBJECTIVE:To develop a minimally invasive interstitial fluid extraction technology (MIET) to monitor postprandial glucose area under the curve (AUC) without blood sampling, we evaluated the accuracy of glucose AUC measured by MIET and compared with that by blood sampling after food intake. METHODS:Interstitial fluid g...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章

    doi:10.1260/2040-2295.4.4.529

    authors: Kuranuki S,Sato T,Okada S,Hosoya S,Seko A,Sugihara K,Nakamura T

    更新日期:2013-01-01 00:00:00

  • Perspectives of nanotechnology in minimally invasive therapy of breast cancer.

    abstract::Breast cancer, the most common type of cancer among women in the western world, affects approximately one out of every eight women over their lifetime. In recognition of the high invasiveness of surgical excision and severe side effects of chemical and radiation therapies, increasing efforts are made to seek minimally...

    journal_title:Journal of healthcare engineering

    pub_type: 杂志文章,评审

    doi:10.1260/2040-2295.4.1.67

    authors: Yang Y,Wang H

    更新日期:2013-01-01 00:00:00

80 条记录 2/2 页 « 12 »